How to maintain the tableware disinfection cabinet

With the improvement of living water products, people pay more and more attention to catering and healthy eating. Tableware disinfection cabinet is an important electrical appliance to ensure the health of tableware. We should pay attention to the maintenance of disinfection cabinet when using it. It can ensure that the function of the tableware disinfection cabinet is not affected, and it can also prolong its service life. The following is a collection of common knowledge of the use and maintenance of the tableware disinfection cabinet . Let's take a look at it together with the Xiaojiaju.


碗筷消毒柜


How to maintain the tableware disinfection cabinet:

1. The tableware can be put into the disinfection cupboard after being washed and drained. The purpose is to shorten the disinfection time and reduce the power consumption.

2, plastic and Other high temperature resistant tableware can only be placed in the upper layer of ozone disinfection low temperature disinfection cabinet, one side is damaged, the lower layer of far infrared disinfection is mainly for ceramics, glass and other tableware.

3, ceramic bowls, plates, cylinders, cans, etc., in the glaze, its enamel, pigments contain toxic lead, cadmium and other heavy metals, usually, these substances are relatively stable, but when exposed to high temperatures, it is easy to overflow. The internal temperature of the disinfection cabinet can be as high as 200 °C under working conditions. Frequently placing food in these sterilized colored porcelains can contaminate food and endanger health. Therefore, the colored porcelainware can only be placed in the low temperature layer when it is placed in the tableware disinfection cabinet for disinfection.

4, bowls, dishes, cups and other tableware should be placed vertically on the shelf, it is best not to stack, in order to ventilate and disinfect as soon as possible.

5. When using the ozone disinfection cabinet, pay attention to whether the ozone generator works normally. If the high-voltage discharge is not heard or the discharge blue light is not visible, the ozone generator may malfunction and should be repaired in time.

6, tableware disinfection cabinet should be placed in a dry and ventilated place, not less than 30 cm from the wall.

7. Do not open the door when it is not necessary during the disinfection of the tableware, so as not to affect the effect.

8. After the disinfection of the tableware is finished, if it is taken after ten minutes, the effect is better. There is a small amount of ozone odor overflow when opening the door. This concentration is not harmful to human health, please rest assured.

9. The water in the water collection box at the lower end of the cabinet should be poured out regularly.

I believe that after reading this article, you should notice how to use it. Only proper use and maintenance can give you a healthy living environment. For more information, please stay tuned for the tracking report of Xiaojiaju.com.